Catalogue
Web V6 Catalogue
Search:
Page 1 of 2
Next
Group:
-->
ECO1005
THERMAL HEAT & FIRE DETECTOR
Ex GST:
85.00
Inc GST:
93.50
ECO1005

ECO1000 Series Conventional Detectors
ECO1000 is a range of photoelectric smoke detectors with an array of advanced features using the latest manufacturing technology with a low profile design and low current draw, and with automatic drift compensation. Operates on 12V and 24V DC systems. A laser-based hand-held remote test unit can be used in conjunction with the range of ECO1000 detectors for alarm test purposes. The unit transmits a coded message, preventing spurious alarms being generated by other laser based devices. With a range of several meters, the hand-held test unit removes the need for any direct physical access to the detector by the user. The range also has an integral LED which illuminates to provide a local alarm signal. This latches on, and remains illuminated until the detector is reset by a momentary power interruption. An optional remote LED annunciator may be used to repeat any alarm signal. With extended warranty. Has approval to EN54 - 7:2000 (Amendment 1) and EN54 - 5:2000 (Amendment 1) Class A1R; CEA 4021.

ECO1005 Thermal Fire Detector
The thermal fire detector uses a state of the art thermal element combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires. The detector incorporates both rate of rise and static elements and is suitable for all areas where the ambient conditions do not normally exhibit rapid changes in temperature.

  • Current consumption type: 55A @ 24VDC (quiescent)
  • Ambient temperature: -30deg C to +70deg C
  • Relative humidity: 5.95% (no condensation)
  • Weight: 70g (plus 45g for standard base)
  • Approval: VdS G201060
  • Dimensions (mm): 40.5 (H) (+ 9.5mm for standard base) ~ 102 (O)


ECO1005

ECO1000 Series Conventional Detectors
ECO1000 is a range of photoelectric smoke detectors with an array of advanced features using the latest manufacturing technology with a low profile design and low current draw, and with automatic drift compensation. Operates on 12V and 24V DC systems. A laser-based hand-held remote test unit can be used in conjunction with the range of ECO1000 detectors for alarm test purposes. The unit transmits a coded message, preventing spurious alarms being generated by other laser based devices. With a range of several meters, the hand-held test unit removes the need for any direct physical access to the detector by the user. The range also has an integral LED which illuminates to provide a local alarm signal. This latches on, and remains illuminated until the detector is reset by a momentary power interruption. An optional remote LED annunciator may be used to repeat any alarm signal. With extended warranty. Has approval to EN54 - 7:2000 (Amendment 1) and EN54 - 5:2000 (Amendment 1) Class A1R; CEA 4021.

ECO1005 Thermal Fire Detector
The thermal fire detector uses a state of the art thermal element combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires. The detector incorporates both rate of rise and static elements and is suitable for all areas where the ambient conditions do not normally exhibit rapid changes in temperature.

  • Current consumption type: 55A @ 24VDC (quiescent)
  • Ambient temperature: -30deg C to +70deg C
  • Relative humidity: 5.95% (no condensation)
  • Weight: 70g (plus 45g for standard base)
  • Approval: VdS G201060
  • Dimensions (mm): 40.5 (H) (+ 9.5mm for standard base) ~ 102 (O)


ECO100RL
LATCHING PLUG-IN DETECTOR BASE, 4 WIRE
Ex GST:
49.00
Inc GST:
53.90
ECO100RL

ECO100RL Plug-In Detector Base - Latching

A variety of detector bases can be used with the ECO1000 detector range. All bases are fitted with a shorting spring to permit circuit testing prior to fitting the detector and have a tamper resistant feature which, when activated prevents removal of the detector without use of a tool. The alarm condition can only be terminated by removal of the supply to the detector and base.

  • The plug in detector base is used with the System Sensor range of detector heads
  • The capability of plugging these detectors into a variety of special bases makes them more versatile than equivalent direct-wired models
  • Suits 2 & 4-wire systems
  • Acepts photo, ion and heat detectors
  • Non-latching or latching versions with change over contacts available
  • Tamper resistant base


ECO100RL

ECO100RL Plug-In Detector Base - Latching

A variety of detector bases can be used with the ECO1000 detector range. All bases are fitted with a shorting spring to permit circuit testing prior to fitting the detector and have a tamper resistant feature which, when activated prevents removal of the detector without use of a tool. The alarm condition can only be terminated by removal of the supply to the detector and base.

  • The plug in detector base is used with the System Sensor range of detector heads
  • The capability of plugging these detectors into a variety of special bases makes them more versatile than equivalent direct-wired models
  • Suits 2 & 4-wire systems
  • Acepts photo, ion and heat detectors
  • Non-latching or latching versions with change over contacts available
  • Tamper resistant base


FIRE025
2012/24 PHOTOELECTRONIC SMOKE DETECTOR
Ex GST:
125.00
Inc GST:
137.50
FIRE025 (2012/24)

Photoelectronic Smoke Detector

Compact, attractive, and easy to install, the system sensor smoke detector is designed to respond to a broad range of fires while providing maximum stability. This model also features low-voltage wiring making it ideal for applications such as apartment buildings and nursing homes. A normally open auxiliary alarm relay with an 8 second delay is available for controlling external functions. Visible LED indicator flashes once every 30 seconds in standby and rapidly (every 0.5 seconds) in alarm when detecting smoke.

12/24VDC operation
Integral T3 sounder
Interconnectable
Built-in silence/test push button
LED indicates standby and alarm modes
A delay on the Form C relay
Chamber integrity check function
9V battery backup (2012/24AUS only)
Backwards compatible
Supply Voltage Range: 10 VDC to 30 VDC
Maximum Standby Current: 60 μA maximum average
Maximum Alarm Current: 50 mA maximum average @ 10~30VDC
P-horn Sound Output Level: 85 dBA @ 3m
Operating Temperature Range: 0°C to 50°C
Humidity: 5% to 93% R.H.



    FIRE025 (2012/24)

    Photoelectronic Smoke Detector

    Compact, attractive, and easy to install, the system sensor smoke detector is designed to respond to a broad range of fires while providing maximum stability. This model also features low-voltage wiring making it ideal for applications such as apartment buildings and nursing homes. A normally open auxiliary alarm relay with an 8 second delay is available for controlling external functions. Visible LED indicator flashes once every 30 seconds in standby and rapidly (every 0.5 seconds) in alarm when detecting smoke.

    12/24VDC operation
    Integral T3 sounder
    Interconnectable
    Built-in silence/test push button
    LED indicates standby and alarm modes
    A delay on the Form C relay
    Chamber integrity check function
    9V battery backup (2012/24AUS only)
    Backwards compatible
    Supply Voltage Range: 10 VDC to 30 VDC
    Maximum Standby Current: 60 μA maximum average
    Maximum Alarm Current: 50 mA maximum average @ 10~30VDC
    P-horn Sound Output Level: 85 dBA @ 3m
    Operating Temperature Range: 0°C to 50°C
    Humidity: 5% to 93% R.H.



      FUL1010
      00040 FIRECAT-X PHOT/ THERML SMOKE DETECTR+RELAY BASE, 12V
      Ex GST:
      110.00
      Inc GST:
      121.00
      FUL1010 (400001FULL-0001)

      Fire Sensor

      Multi-function 12V fire sensor
      Compensates for chamber contamination
      User selectable sensing functions - choice of optical, optical-heat, rate of rise heat or fixed temperature heat sensor
      Latching or auto resetting alarm relay
      Multifuctional LED indicator
      Dimensions (mm): 57 (H) 107 ()



        FUL1010 (400001FULL-0001)

        Fire Sensor

        Multi-function 12V fire sensor
        Compensates for chamber contamination
        User selectable sensing functions - choice of optical, optical-heat, rate of rise heat or fixed temperature heat sensor
        Latching or auto resetting alarm relay
        Multifuctional LED indicator
        Dimensions (mm): 57 (H) 107 ()



          TAKX1290
          FS3500E FLAME SENSOR, MESSAGE TYPE/INDOOR, ULTRAVIOLET RAY DETECTION
          Ex GST:
          522.00
          Inc GST:
          574.20
          TAKX1290 (FS3500E)

          Flame Sensor

          Message can be announced just once or repeated twice
          2 levels of sensitivity and 4 steps of timer options
          2 options of power supply (AA alkaline battery or external wiring 10 ~ 30V DC)
          N.O / N.C selectable signal output and N.C tamper output
          Customised recorded message




            TAKX1290 (FS3500E)

            Flame Sensor

            Message can be announced just once or repeated twice
            2 levels of sensitivity and 4 steps of timer options
            2 options of power supply (AA alkaline battery or external wiring 10 ~ 30V DC)
            N.O / N.C selectable signal output and N.C tamper output
            Customised recorded message




              Page 1 of 2
              Next
              Go to page: